WINPOWER ECO EXP

TXAEU 4370÷6660

Chladící výkon: 352.7÷641.5 kW

Topný výkon: 363.3÷645.5 kW

  •  Multi-purpose units with TER up to 8
  •  Extended operating limits
  •  Units for systems with 2, 4 and 6 pipes
  •  SEER up to 5.29 with FIEC accessory (EC fans) and SCOP up to 3.89
  •  R454B eco-friendly gas
  • Certifikace Eurovent
  • Jednotka pro venkovní instalaci
  • Nízké GWP

EXPsystems – Air cooled multi-purpose ecological system with axial fans. Range with scroll hermetic compressors and R454B refrigerant gas.

 

• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.

• Up to 6 capacity steps with high efficiency at partial loads.
• Main and secondary heat exchangers: crossed flow stainless steel plate exchangers, complete with antifreeze heater, closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: finned coil with copper pipes and aluminium fins.
• Fan: external rotor axial type electric fans equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed adjustment.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
– fan and compressor thermal magnetic circuit breakers, heat exchanger antifreeze heater;
– display of cooling circuit high and low pressure;
– electronic expansion valve;
– clock board;
– Master/Slave control up to 4 units in parallel;
– control of Variable Primary Flow (VPF_R).

 

Versions

• T – High efficiency version.
Q – Super silenced version complete with compressor technical compartment soundproofing and reduced speed fans.

 

Models

• TXAETU: EXPsystems unit.
• TXAEQU: super silenced EXPsystems unit.

 

Factory fitted accessories

• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the main and secondary/recovery heat exchanger low or high head set-ups.
• Inverter pump control for unit start-up.
• Desuperheater.
• Condensing control with fans with EC motor.
• Condensing control with over-pressure fans (T version only).
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Soft starter.
• Compressor box and soundproofed cooling circuit.
• Compressor soundproof enclosures.
• Cooling circuit outlet valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Coil protection nets or buffer panels.
• Bottom compartment protection nets.
• Pre-painted copper/aluminium coils, copper/copper or with hydrophilic treatment.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Electrical panel antifreeze heater, coil tanks, electric pumps and desuperheater, if applicable.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7” display.
• Spring anti-vibration mounts.
• Protective packaging.

 

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Potřebujete podobné řešení, pomoct nebo poradit?

Kontaktujte nás