Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit with water-cooling system. Range with scroll hermetic compressors and R410A refrigerant gas.
Construction features
• Compressor: hermetic rotary scroll complete with thermal protection and crankcase heater.
• Primary side (user) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
• Disposal unit side (well/mains/geothermal probes) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch (for THHEY).
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
– compressor circuit breaker switches;
– display of cooling circuit high and low pressure;
– Master/Slave control up to 4 units in parallel;
– clock board;
– 0-10V analogue signal for condensing/evaporating control performed by external device;
– control of Variable Primary Flow (VPF_R).
Versions
• LT – Hot water production up to 52°C.
• HT – Hot water production up to 55°C.
Models
• TCHEY: unit designed for cooling only.
• THHEY: heat pump unit.
Factory fitted accessories
• PUMP primary side (user): with single or double electric pump, including an automatic pump in standby, complete with expansion tank, safety valve, water fill/drain valve, air vent valve and pressure gauge. The electric pumps are available in the low or high pressure head versions. ➔
• PUMP disposal side (geothermal probes/dry cooler): with single or double electric pump regulated via inverter including an automatic actuation pump in standby. ➔
• Desuperheater. ➔
• 100% heat recovery unit (mod. 245-4360). ➔
• Water circuit heat pump (for TCHEY only).
• Inverter pump control for unit start-up.
• Power factor correction capacitors (cosφ > 0.94).
• Soft-starter.
• Energy parameter measuring device.
• Cooling circuit outlet and inlet valves.
• Refrigerant leak detector.
• Forced limit of power consumption.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Silenced set up.
• Control of min/max power supply voltage.
• Low temperature water production.
• Digital input for double set-point.
• 4-20mA analogue signal for shifting set-point.
• Interfaces for serial communication with other devices.
• Rubber anti-vibration mounts.
Separately supplied accessories
• 3-way modulating condensing control valve.
• 2-way modulating condensing control valve.
• Outdoor air temperature probe for set-point compensation.
• Free-cooling kit (mod. 245-2185).
• Water filter.
• Remote keypad with display.
• Thermostat with display.
• Serial converter (RS485/USB).
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.